On your PrimeLab 2.0 5.5" colour HD-display you will receive step-by-step guidance through every
test you are performing, plus animated clips showing graphically what needs to be done to
successfully perform the measurement. Each test result will be saved to a sampling point in
conjunction with the selected operator name, time-stamp and dilution factor, if chosen.
PrimeLab 2.0 makes testing easy:
Available for you soon:
• Scanning a reagent QR code (! Last sampling point used will be pre-set. Parameter to be tested
can be selected from a dropdown menu, which shows suitable parameters according to the QR-
code scanned !)
• Scanning a sampling point QR code (! Last parameter tested will be pre-set. Sampling point will be
pre-set according to the QR code information !)
Launch a test procedure by...:
• Tapping the “TEST” icon on the main menu (! Sampling point and parameter are pre-set with the
ones from last measurement!)
• Tapping on “New Measurement” from the ‘Sampling Point‘ menu (! The sampling point from where
you initiate “New Measurement“ will be pre-selected !)
How to enter the TEST menu
Almost every test requires a ZERO measurement. The ZERO value determines the colour/turbidity
of your water sample in order to eliminate any pre-colouration or turbidity. PrimeLab 2.0 stores the
last ZERO value to be able to perform more than one test with the same undiluted water source (!)
without having to repeat the ZERO measurement each time. Since some parameters use different
ZERO methods, such as 10ml water sample or 5ml water sample plus 5ml deionised water,
PrimeLab 2.0 recognises the ZERO type of each measurement and only offers OTZ if the following
measurement matches the ZERO type of the last measurement taken.
Intelligent OTZ (One-Time-Zero)
• Choose/change the dilution-factor if applicable. Not every parameter offers dilution.
If you do not want to repeat the test and continue with the next step, press the arrow button.
Once you entered the ‘TEST‘ menu...
• Choose/change the sampling point for which the test shall be performed from the drop-down menu.
• Choose/change the parameter you want to test from the drop-down menu.
• Choose/change the operator performing the test from the drop-down menu.
• Press “START” to start the measurement.
• Follow the instructions on the screen
After the result is displayed, you have the option to repeat the test. To do so, press the Repeat button.
Perform a measurement
Test
Continued...
PrimeLab
2.0
Summary of Contents for Primelab 2.0
Page 17: ...EMPTY due to technical reasons 16 PrimeLab2 0...
Page 31: ...EMPTY due to technical reasons 30 PrimeLab2 0...
Page 35: ...EMPTY due to technical reasons 34 PrimeLab2 0...
Page 37: ...EMPTY due to technical reasons 36 PrimeLab2 0...
Page 41: ...40 EMPTY due to technical reasons PrimeLab2 0...
Page 45: ...due to technical reasons EMPTY 44 PrimeLab2 0...
Page 252: ...NTU standards should be stored at 5 25 C T197 204 T197 204...
Page 261: ...EMPTY due to technical reasons 48 PrimeLab2 0...
Page 267: ...EMPTY due to technical reasons 54 PrimeLab2 0...
Page 283: ...70 due to technical reasons EMPTY PrimeLab2 0...
Page 293: ...due to technical reasons EMPTY 80 PrimeLab2 0...