Parameter Description
VD300 Series Inverter User Manual
- 158 -
6.14 P14 Error Record Parameter Group
P14.00
Fault Record Selection
0~3 ( 0: current fault, 1: Last fault, ID is
larger, the earliest failure)
0
○
This parameter is used to select the user needs to check when failure keep records. Note: the bigger
the ID number is, the earlier the inverter failure time is.
Error
code
Error code description
Error
code
Error code description
0
No fault
Er001
Acceleration run overcurrent
(hardware)
Er002
Deceleration run overcurrent (hardware)
Er003
Constant speed run overcurrent
(hardware)
Er004
Acceleration run overcurrent (software)
Er005
Deceleration run overcurrent
(software)
Er006
Constant speed run overcurrent
(software)
Er007
Acceleration run overvoltage
Er008
Deceleration run overvoltage
Er009
Constant speed run overvoltage
Er010
Bus under voltage
Er011
Motor overload
Er012
Inverter overload
Er013
Input side phase loss
Er014
Output side phase loss
Er015
Module overheat
Er016
Current over limit fault
Er017
External fault
Er018
Communication fault
Er019
Current detecting circuit fault
Er020
Motor self-learning error
Er021
EEPROM read-write fault
Er022
PID feedback over limit fault
Er023
PID feedback break line fault
Er024
Short circuit to ground upon power on
Er025
Breaking unit fault
Er026
Reserved
Er027
Running time reached
Er028
Power-on time reached
Er029
Offload
Er030
Reserved
Er031
Reserved
Er032
Reserved
Er033
Reserved
Er034
Overheat
Er035
Reserved
Er036
Electronic overload
Er037
Reserved
Er041
User-defined fault 1
Er042
User-defined fault 2
Er043
User-defined fault 3
Er044
User-defined fault 4
Er060
manufacturer defined fault 1
Er061
manufacturer defined fault 2
Er090
Keypad communication fault (keypad
CPU error)
Er091
Parameters upload fault (keypad
CPU error)
Er092
Parameters download fault (keypad CPU
error)
Summary of Contents for VD300 Series
Page 2: ......