Function Parameter Table
VD300 Series Inverter User Manual
- 52 -
P04.21
Energy
Saving
Running Selection of
Motor 1
0: Disabled
1: Enabled
0
◎
P05 Input Terminal Parameters Group
Function
Code
Parameter Name
Setting Range
Factory
Default
Value
Property
P05.00
Terminal Control
Running Mode
0: Two-line mode 1
1: Two-line mode 2
2: Three-line mode 1
3: Three-line mode 2
4: Alternate control
5: Back and forth control
0
◎
P05.01
DI1 Input Function
Selection
1
◎
P05.02
DI2 Input Function
Selection
2
◎
P05.03
DI3 Input Function
Selection
4
◎
P05.04
DI4 Input Function
Selection
6
◎
P05.05
DI5 Input Function
Selection
8
◎
P05.06
HDI1 Input Function
Selection (Can select
HS pulse input)
0
◎
P05.07
DI7 Input Function
Selection
(Extension card)
0
◎
P05.08
DI8 Input Function
Selection
(Extension card)
0
◎
P05.09
DI9 Input Function
Selection
(Extension card)
0: No function
1: Forward running (FWD)
2: Reverse running (REV)
3: Three-line mode run control
4: Forward Jog (FJOG)
5: Reverse Jog (RJOG)
6: Coast to stop
7: Run pause
8: Fault reset (RESET)
9: External fault input
10: Frequency setting increase (UP)
11: Frequency setting decrease (DOWN)
12: Frequency UP/DOWN setting clear
13: Frequency UP/DOWN setting clear
temporary
14: Acceleration/deceleration time
selection 1
15: Acceleration/deceleration time
selection 1
16: Multi stage speed terminal 1
17: Multi stage speed terminal 2
18: Multi stage speed terminal 3
19: Multi stage speed terminal 4
20: Multi-stage speed pause
21: Immediate DC braking
22: Deceleration DC braking
23: External stop
24: Emergency stop
25: PID control pause
26: Reverse PID action direction
27: PID parameter switchover
0
◎