Function Parameter Table
VD300 Series Inverter User Manual
- 48 -
P03.06
Speed Loop
Parameter Switchover
Frequency Point 2
P03.03~P00.07 (max output frequency)
10.00Hz
○
P03.07
Speed Loop Output
Filter
0~8 (corresponding 0~2^8/10ms)
0
○
P03.08
Vector Control Slip
Compensation
Coefficient (Motoring
Condition)
50.0%~200.0%
100.0%
○
P03.09
Vector Control Slip
Compensation
Coefficient
(Generating Condition)
50.0%~200.0%
100.0%
○
P03.10
Current Loop
Proportion Coefficient
P
0~60000
1000
○
P03.11
Current Loop Integral
Coefficient I
0~60000
1000
○
P03.12
Torque Setting Mode
Selection
0: Function code P03.13
1: AI1
2: AI2
3: AI3 (extension card)
4: High speed pulse input
5: Communication setting
Notes: 100% of 1~4 corresponding
P03.13
0
○
P03.13
Keypad Setting Torque
-300.0%~300.0% (rated motor current)
100.0%
○
P03.14
Torque Setting Filter
Time
0.000s~10.000s
0.100s
○
P03.15
Source Setting of
Frequency Upper Limit
of Forward in Torque
Control
0: Function P03.17
1: AI1
2: AI2
3: AI3 (extension card)
4: High speed Pulse input
5: Communication setting
Notes: 100% of 1~4 relative to the
maximum output frequency
0
○
P03.16
Source Setting of
Frequency Upper
Limit of Reverse in
Torque Control
0: Function code P03.18
1: AI1
2: AI2
3: AI3 (extension card)
4: High speed Pulse input
5: Communication setting
Notes: 100% of 1~4 relative to the
0
○