Parameter Description
VD300 Series Inverter User Manual
- 164 -
6.19 P29 User Parameter Group
P29.00
User Password
0~65535
0
○
Any non-zero number can be set, and then the password protection function will be enabled.
When enter the menu next time, must input password correctly, otherwise can’t view and modify the
function parameters, please remember setup user password correctly.
Set P29.00 to 0000: Clear the previous setup user password and disable the password protection
function.
P29.01
Parameter Initialization
0: No operation
1: Restore the factory parameter
2: Clear the fault record
3: Clear accumulative running and
power-on time
4: Date upload (inverter to panel)
5: Date download (panel to inverter)
0
◎
Recover manufacturer parameter: inverter function parameter mostly is recovered to manufacturer
parameter, but motor parameter, error record message, accumulate run time, accumulate power-on
time are not recovered.
Clear error record: clear inverter error record message.
Clear accumulate run and power-on time: used to clear accumulate run and power-on time of inverter
record.
Data upload: used to upload all user parameters to the CPU display board.
Data download: for the CPU display board stored on the user parameters are downloaded to the
control board.
P29.02
Product Code
0~65535
Factory
Setting
●
P29.03
Software Versioning
1.00~10.00
Factory
Setting
●
P29.04
Inverter Rate Power
0.4kW~1000.0kW
Factory
Setting
●
P29.05
Inverter Rate Voltage
220V~1140V
Factory
Setting
●
P29.06
Inverter Rate Current
2.4A~2000.0A
Factory
Setting
●
P29.07
Factory Use
☆
P29.08
Factory Use
☆
P29.09
Factory Use
☆
P29.10
Factory Use
☆
P29.11
Factory Use
☆
Above parameter is used to check over inverter manufacturer setting and inverter critical parameter,
only for user to review.