Function Parameter Table
VD300 Series Inverter User Manual
- 80 -
P20.09
Motor 2 Stator and
Rotor Mutual
Inductance
0.0mH~6553.5mH
Model
Dependent
○
P20.10
Motor 2 No-load
Current
0.0A~P20.03 (rate motor 2 current)
Model
Dependent
○
P21 Motor 2 V/F Control Group
Function
Code
Parameter Name
Setting Range
Factory
Default Value
Property
P21.00
Motor 2 V/F Curve
Setting
0: Straight line V/F curve
1: Multi-stage V/F curve
2: 1.3#power lower torque V/F curve
3: 1.7# power lower torque V/F curve
4: 2.0# power lower torque V/F curve
5: V/F complete separation
6: V/F half separation
0
◎
P21.02
Motor 2 V/F
Frequency Point 1
0.00Hz~P21.04
0.00Hz
○
P21.03
Motor 2 V/F Voltage
Point 1
0.0%~110.0%
(rated voltage of motor 2)
0.0%
○
P21.04
Motor 2 V/F
Frequency Point 2
P21.02~ P21.06
0.00Hz
○
P21.05
Motor 2 V/F Voltage
Point 2
0.0%~110.0% (rated motor 2 voltage)
0.0%
○
P21.06
Motor 2 V/F
Frequency Point 3
P21.04~ P00.07
0.00Hz
○
P21.07
Motor 2 V/F Voltage
Point 3
0.0%~110.0% (rated motor 2 voltage)
0.0%
○
P21.08
Motor 2 V/F Slip
Compensation Gain
0.0%~200.0%
100.0%
○
P21.09
Motor 2 Torque Boost
0.0%: Auto torque boost
0.1%~10.0%
0.0%
○
P21.10
Motor 2 Torque Boost
Cut Off
0.0%~50.0%
(relate to rated motor 2 frequency)
20.0%
○
P21.11
Low
Frequency
Suppression
Oscillation Factor of
Motor 2
0~100
10
○
P21.12
High
Frequency
Suppression
Oscillation Factor of
Motor 2
0~100
10
○