VD300 Series Inverter User Manual
Parameter Description
- 111 -
44
Power consumption
holding
Keep the power consumption counter, but the inverter present run
of power consumption is not accumulated (electric level effective);
45
Swing frequency
pause (stop at current
frequency)
Inverter output as current frequency, swing frequency function
paused;
46
Swing frequency reset
(back to center
frequency)
Inverter output as center frequency, swing frequency function
paused;
47
Motor switchover
If the function is set as enabled, switchover motor 1 to motor 2,
meanwhile motor parameter and corresponding control parameter
will be switchover at the same time, level effective;
48
Clear the current
running time
When the terminal is effective, the time of the operation of the
frequency converter is cleared, and the function needs to be
matched with the setting arrival time (P09.32) of the current
running time;
49
User-defined failure
input 1
When the user defined external fault normally closed signal to the
inverter, the inverter report a fault, and according to the fault
protection action to deal with the fault;
50
User-defined failure
input 2
When the user defined external fault normally closed signal to the
inverter, the inverter report a fault, and according to the fault
protection action to deal with the fault;
51
User-defined failure
input 3
When the user defined external fault normally closed signal to the
inverter, the inverter report a fault, and according to the fault
protection action to deal with the fault;
52
User-defined failure
input 4
When the user defined external fault normally closed signal to the
inverter, the inverter report a fault, and according to the fault
protection action to deal with the fault;
53
PID preset output
disable
PID effective, do not have a preset output, but directly to the PID
adjustment.
Schedule 1 is MS speed instruction function description
K4
K3
K2
K1
Direct setting
Corresponding Parameter
OFF
OFF
OFF
OFF
MS speed 0
P11.00
OFF
OFF
OFF
ON
MS speed 1
P11.01
OFF
OFF
ON
OFF
MS speed 2
P11.02
OFF
OFF
ON
ON
MS speed 3
P11.03
OFF
ON
OFF
OFF
MS speed 4
P11.04
OFF
ON
OFF
ON
MS speed 5
P11.05
OFF
ON
ON
OFF
MS speed 6
P11.06
OFF
ON
ON
ON
MS speed 7
P11.07
ON
OFF
OFF
OFF
MS speed 8
P11.08
ON
OFF
OFF
ON
MS speed 9
P11.09
ON
OFF
ON
OFF
MS speed 10
P11.01