Function Parameter Table
VD300 Series Inverter User Manual
- 68 -
tuning frequency
LED ten’s digit:
0: B frequency allows for superposition
fine tuning frequency
1: B frequency prohibit superposition fine
tuning frequency
P10 Keyboard and Display Parameters Group
Function
Code
Parameter Name
Setting Range
Factory
Default
Value
Property
P10.00
STOP/RESET Key
Stop Function
0: Only enabled to panel control
1: Enabled to panel and terminal control
at the same time
2: Enabled to panel and communication
at the same time
3: Enabled to all control mode
0
○
P10.01
REV/JOG Key
Function
0: No function
1: Jog running
2: FWD/REV switchover
3: Coast to stop
4: Clear up/down & ^/v key setup
frequency
5: Shift key switchover display state
6: To achieve run command given way
according to switchover sequence
7: Quick debugging mode (according to
factory parameter debugging)
8: Modify rapidly set frequency
1
◎
P10.02
JOG/REV Key Run
Command Channel
Switchover
Sequential Selection
0: Keyboard control ←→ terminal control
1: Keyboard control ←→ communication
control
2: Terminal control ←→ communication
control
3: Keyboard control → terminals
Control → communication control
3
○
P10.03
Display Running
Lower Bit
0x0000~0xFFFF
BIT0: Running frequency (Hz light on)
BIT1: Set frequency (Hz flash)
BIT2: Bus voltage (V light on)
BIT3: Output voltage (V light on)
BIT4: Output current (A light on)
BIT5: Run speed (RPM on)
BIT6: Output power (% light on)
BIT7: Output torque (% light on)
BIT8: PID setting value (% flash)
0x003F
○
Summary of Contents for VD300 Series
Page 2: ......