VD300 Series Inverter User Manual
Function Parameter Table
- 49 -
maximum output frequency
P03.17
Frequency Upper Limit
Keypad Setting of
Forward in Torque
Control
0.00Hz~P00.07 (Max output frequency)
50.00Hz
○
P03.18
Frequency Upper Limit
Keypad setting of
Reverse in Torque
Control
0.00Hz~P00.07 (Max output frequency)
50.00Hz
○
P03.19
Electric Torque Upper
Limit Source Setting
0: Function code P03.21
1: AI1
2: AI2
3: AI3 (extension card)
4: HS pulse input
5: Communication setting
Note: Setting mode 100% of 1-4
corresponds to three times of the motor
current
0
○
P03.20
Braking Torque Upper
Limit Source Setting
0: Function code: P03.22
1: AI1
2: AI2
3: AI3( extension card)
4: HS pulse input
5: Communication setting
Note: Setting mode 100% of 1-4
corresponds to three times of the motor
current
0
○
P03.21
Electric Torque Upper
Limit Keypad Setting
0.0%~300.0% (rated motor current )
180.0%
○
P03.22
Braking Torque Upper
Limit Keypad Setting
0.0%~300.0% (rated motor current)
180.0%
○
P03.23
Max Voltage Limit
0.0%~120.0%
100.0%
◎
P03.24
Pre-excitation Time
0.000s~10.000s
0.300s
○
P03.25
Weak Magnetic
Coefficient in Constant
Work Area
0.1~2.0
0.3
○
P03.26
Min Weak Magnetic
Point in Constant
Work Area
10%~100%
20%
○
P03.27
Vector Control Weak
Magnetic Proportion
Gain
0~4000
1200
○
P03.28
Low Frequency
Torque Compensation
Coefficient
0.0%~50.0%
0.0%
○