VD300 Series Inverter User Manual
Function Parameter Table
- 43 -
P00.05
Rang of Frequency
Command Source B
0: Relative to maximum frequency
1: Relative to frequency source A
0
○
P00.06
Frequency output
lower limit after
superposition
-100%~100%(100% corresponding to
P00.07)
0.0%
◎
P00.07
Maximum Output
Frequency
P00.09~650.00Hz
50.00Hz
◎
P00.09
Running Frequency
Upper Limit Digital
Setting
P00.10~P00.07
50.00Hz
○
P00.10
Running Frequency
Lower Limit Digital
Setting
0.00Hz~P00.09
0.00Hz
○
P00.11
Keypad Set
Frequency
0.00Hz~P00.07 (max output frequency)
50.00Hz
◎
P00.12
MS Speed Command
Stage 0 Command
Source
0: Function code P11.00
1: Function code P00.11
2: AI1
3: AI2
4: AI3 (extension card)
5: High speed pulse
6: PID control set
7: Keypad potentiometer
0
◎
P00.14
Acceleration Time 0
0.0s~3600.0s
Model
dependent
○
P00.15
Deceleration Time 0
0.0s~3600.0s
Model
dependent
○
P00.16
Acceleration /
Deceleration Time
Reference Frequency
0: Max output frequency
1: Set frequency
0
○
P00.17
Operation Direction
Selection
0: Running in the default direction
1: Running in the opposite direction
0
◎
P00.18
Reverse Forbid
0: Allow motor reverse
1: Forbid motor reverse
0
○
P00.19
Carrier Frequency
Setting
1.0kHz~16.0kHz
Model
dependent
○
P00.21
Parameter
Lock Selection
0: Lock disabled
1: Lock enabled, not allow to change
other parameters except the current one
2: Not allow to operation parameter
initializing function code
0
◎
P00.22
Inverter G/P Type
0: G type
1: P type
0
○