VD300 Series Inverter User Manual
Function Parameter Table
- 53 -
28: Pre-excitation command
29: Torque control disabled
30: Acceleration/deceleration disabled
31: Switchover between set A and set B
32: Switchover between combined set
and set A
33: Switchover between combined set
and set B
34: Simple PLC stop reset
35: Simple PLC pause
36: Counter trigger
37: Counter reset
38: Length trigger
39: Length reset
40: Command switchover to keypad
41: Command switchover to terminal
42: Command switchover to
communication
43: Power consumption clear
44: Power consumption holding
45: Swing frequency pause (stop at
current frequency)
46: Swing frequency reset (back to center
frequency)
47: Motor switchover
48: Clear the current running time
49: User-defined failure input 1
50: User defined failure input 2
51: User defined failure input 3
52: User defined failure input 4
53: PID preset output disable
54~63: Reserved
P05.10
HDI1 Terminal
Function Selection
0: HS pulse input
1: Switch signal input
0
◎
P05.11
Digit Input Polarity
Selection
0x000~0x1FF: bit0~bit8 corresponding
with
DI1~DI5, the binary bit set value of
DHI1, DI7~DI9 corresponding to the
function:
0: Switch closed effective
1: Switch open effective
0x000
◎
P05.12
DI Filter Time
0.000s~1.000s
0.010s
○
P05.13
Low Limited of AI1
Voltage
-10.00V~P05.15
0.00V
○