Parameter Description
VD300 Series Inverter User Manual
- 154 -
P13.09
Time
DO
Output
Time
Output
current
P13.10
DO
Output
Fig 6.12-4
Diagram of output current over limit detecting
P13.12
Overvoltage Stall
Protective
0: Disabled
1: Enabled
1
○
120%~150%
(standard bus voltage, 380V)
140%
P13.13
Overvoltage Stall
Protective Voltage
120%~150%
(standard bus voltage, 220V)
120%
○
Used for setting the overvoltage threshold voltage of inverter DC bus and overvoltage whether to
open stall protection. For larger inertia but with no configured braking circuit, if prohibit overvoltage
stall protection inverter will easily jump over overvoltage error, if open overvoltage stall protection then
resulting in inverter actual decelerating time will be delayed. If inverter built-in braking unit and
configured braking resistor. P13.13 is the braking unit threshold voltage when overvoltage.
Time
Bus
voltage
Time
Output
frequency
P13.13
Fig 6.12-5 Diagram of over voltage under speed
P13.14
Dynamic Braking
Enable
0: Disabled
1: Enabled
1
○
220VAC corresponding:
380.0VDC
P13.15
Dynamic Braking
Voltage
200.0VDC~2000.0VDC
380VAC corresponding:
700.0VDC
○