7.1.6 Hoisting motor
Standard hoists are equipped with two-speed squirrel-cage motors, which are especially designed and
manufactured for hoisting duty. The motors incorporate a cylindrical rotor and class F insulation, and are conform to
the protection standard IP54/DIN40050.
Optionally, the hoist can be equipped with a frequency converter and specially designed motors for this duty. These
are one-speed squirrel-cage motors with increased insulation of the windings. In addition, these motors are
equipped with a speed sensor as a standard.
1. Fan cover
2. Fan
3. Brake
4. Brake disc
5. Fixing screws for motor
6. Friction disc
Assembly
See section “Hoisting machinery assembly” for details.
7.1.6.1 Maintenance of hoisting motor
1
2
Check that the hoisting motor operates properly when loaded.
Check for any excessive noise, vibration and/or heat.
Clean the cooling-ribs surface when needed.