Condition monitoring unit Inspection
1
2
Check that none of the fault-indicating LEDs are lit up, and
that the display does not show an error message.
Write down the primary monitoring values and keep a log of
them.
Note: If any of the red alarm lights is lit or blinking, check out if this is caused by a normal supervisory function.
If this is not the case, and the problem still occurs, follow the troubleshooting instructions given in the
component-specific Service Manual.
7.4.3 Frequency converters
The electrical cubicle on the hoist contains a frequency converter that controls the rotation speed of the traveling
motor, according to the commands given by the operator.
The frequency converter has signal LEDs or a display indicating its operating status and possible malfunction.
Refer to the Service Manual of the respective frequency converter for details.
The parameters of the frequency converter are pre-set at the factory, and usually do not require re-adjustment. In
case re-adjustment is needed, refer to the Service Manual of the respective frequency converter for details.
0.7 kW frequency converter
2.2 kW frequency converter
4 kW frequency converter
1. Connectors
2. Signal LEDs / Display
3. Parameter switches