1
Filter, control cabinet
Fig. 71110
1. Shut down the machine properly, secure the MAIN SWITCH
and secure with a padlock.
2. Pull out the fan cover:
3. Clean and blow out the filters and fans with compressed air.
4. Replace all four filters if they are very dirty.
5. Reinstall the cover.
6. Switch on the system again in manual mode.
7. Check whether airflows can be felt.
BendMaster: switch cabinet
Maintenance interval: 1000 operating hours
1. Shut down the machine properly, secure the MAIN SWITCH
and secure with a padlock.
5
‐
18
Electrical components
2015-06-01
B579EN
106425:
Clean the Peltier cooler