3.
Switching on and referencing the
BendMaster
3.1
Switching on the BendMaster
Condition
■
The compressed air supply is switched on.
1. Turn on the BendMaster's main switch. The control starts up
automatically.
The TruBend has its own main switch, see TruBend opera-
tor's manual.
2. Wait for the control to start up.
3. Log on the user and request write permission. The following
preset users are available for selection:
−
Operator.
−
Programmer: operator (producing parts).
−
Administrator: operator (retracting parts).
−
Service. TRUMPF Service engineer.
−
Developer.
Notes
The operator does not require a password. All other users
require the corresponding password.
Users can be created and existing users edited in the
">
Service
>
User configuration
menu
4. Set the CONTROL ON key switch at the TruBend to 1.
5. Turn the BendMaster key switch on the mounting device for
the portable manual control unit to the desired operating
mode.
6. Release all EMERGENCY STOP buttons:
−
EMERGENCY STOP on the control panel, on the porta-
ble manual control unit, on all posts of the safety fencing,
on the inside of post 4 and on the control and control
panel of the press brake.
−
In automatic mode: close all doors of the safety fencing.
−
In automatic operating mode: press the GREEN button
on the mounting device for the portable manual control
unit.
−
In manual operating mode: press the ENABLE KEY but-
ton.
7. Referencing the BendMaster
4
‐
38
Switching on and referencing the BendMaster
2015-06-01
B579EN
Summary of Contents for BendMaster 150
Page 1: ...Operator s manual BendMaster TruBend Cell 5000...
Page 2: ......
Page 3: ...Operator s manual BendMaster TruBend Cell 5000 Original operator s manual Edition 2015 06 01...
Page 6: ...II Before you proceed 2015 06 01 B579EN...
Page 16: ...0 10 Table of contents 2015 06 01 B579EN...
Page 44: ...1 28 Disassembly and disposal 2015 06 01 B579EN...