7. Pneumatic components
7.1
Maintenance Instructions
Press brake: compressed air supply
Maintenance interval: Annually
From version S08.00.
The horn for the audible air pressure monitoring is located in the
switch cabinet for options. The test the horn is done by closing
the air supply to the TruBend.
Note
Turning off the compressed air in the switch cabinet for
options does
not
lead to a warning signal.
1. Close the compressed air shut-off valve under the press
brake's switch cabinet. An audible warning signal must
sound.
1
Stopcock
Compressed air unit under the press brake switch cabi-
net
Fig. 71115
2. If required: contact Technical Service.
5
‐
24
Pneumatic components
2015-06-01
B579EN
106523:
Checking the audible
compressed air monitoring