91
© Tieline Research Pty. Ltd. 2019
Bridge-IT Manual v4.0
Configuring a Fuse-IP Remote Client
1. Open the HTML5 Toolbox Web-GUI and click
Transport
and then
Fuse-IP
.
2. Click the
Fuse-IP Mode
drop-down menu and select
Client
as the Fuse-IP mode if you
are dialing the studio codec. Note: the studio codec should be configured in server mode.
3. Enter the
Fuse-IP Server Address
, which is the public static IP address of the server
codec at the studio. Then enter the server codec's serial number in the
Server Serial
Number
text box. Leave the default
Fuse-IP Port
as
8999
in most situations unless this
port is already in use, e.g. you have multiple codecs behind a firewall using Fuse-IP,
therefore you need to allocate a different port for each Fuse-IP tunnel. Note: the port
number on the client and server codecs must be the same. Configure the
Inactivity
Timeout
if you want to turn the Fuse-IP tunnel off after a predetermined time period to
save data, then click
Save
. Note:
Inactivity Timeout
can be configured from 0 to 1440
minutes. Enter
0
to disable the timeout.
4. Click the Fuse-IP
On/Off
button to create a Fuse-IP tunnel between the server and client
codecs. Note:
Connected
should be displayed after a few seconds if both codecs are
configured correctly and Fuse-IP is enabled on both codecs.
Summary of Contents for Bridge-IT
Page 15: ...15 Tieline Research Pty Ltd 2019 Bridge IT Manual v4 0 Codec Menu Overview...
Page 16: ...16 Bridge IT Manual v4 0 Tieline Research Pty Ltd 2019 Connect Menu...
Page 17: ...17 Tieline Research Pty Ltd 2019 Bridge IT Manual v4 0 IP Setup Menu Navigation...
Page 18: ...18 Bridge IT Manual v4 0 Tieline Research Pty Ltd 2019 Settings Menu...
Page 158: ...158 Bridge IT Manual v4 0 Tieline Research Pty Ltd 2019 4 Click Yes in the confirmation dialog...
Page 217: ...217 Tieline Research Pty Ltd 2019 Bridge IT Manual v4 0...