120
Bridge-IT Manual v4.0
© Tieline Research Pty. Ltd. 2019
6. Follow the instructions on the right-hand side of the panel to configure the transport settings for
the connection, then click
Next
. Note: only the first connection dialed in a multi-unicast
program can encode and decode audio. All other connections are unidirectional and encode
only.
Important Note:
See
for detailed information on RS232 data.
Only in-band auxiliary data using the Music or MusicPLUS algorithms is possible when
connecting to G3 Commander and i-Mix codecs.
7. Configure the IP address, ports, and then specify which streaming interface is used to dial this
connection, e.g.
Primary
(
LAN / ETHERNET
port and default setting) or
VLAN
if configured.
Note: By default
Any
will select
Primary
.
Important Notes:
The
Remote Audio Port
is the codec port at the remote end of the link
to which you are sending audio. The
Local Audio Port
is the port used by the local codec
to receive audio from the remote codec. When
Tieline Codecs
is the
Session Protocol
selected (using Tieline session data), the default port value for the
Local Session Port
and
Local Audio Port
is
Automatic
. Note:
Automatic
indicates that the codec will
arbitrarily allocate the local port value and send this information to the codec to which you
are dialing. Click to deselect the
Automatic
check-box and change this setting.
Click
Save Program
to save the program with the default algorithm, jitter and FEC settings which
are physically entered in the codec. Alternatively, click
Next
to specify individual algorithm, jitter
buffer, FEC and auto reconnect settings for this audio stream (recommended).
8.
Click the drop-down arrows on the right-hand side of each text box to adjust the
Encoding
,
Sample rate
or
Bit rate
options.
Summary of Contents for Bridge-IT
Page 15: ...15 Tieline Research Pty Ltd 2019 Bridge IT Manual v4 0 Codec Menu Overview...
Page 16: ...16 Bridge IT Manual v4 0 Tieline Research Pty Ltd 2019 Connect Menu...
Page 17: ...17 Tieline Research Pty Ltd 2019 Bridge IT Manual v4 0 IP Setup Menu Navigation...
Page 18: ...18 Bridge IT Manual v4 0 Tieline Research Pty Ltd 2019 Settings Menu...
Page 158: ...158 Bridge IT Manual v4 0 Tieline Research Pty Ltd 2019 4 Click Yes in the confirmation dialog...
Page 217: ...217 Tieline Research Pty Ltd 2019 Bridge IT Manual v4 0...