108
Specifications
Available
Functions
External
communication
function (RS-232C)
(TE-LF632 only)
Allows communication with a network system to output the status of the pump
(flow rate, alarms, etc.) via RS-232C.
Free message function
(TE-LF632 only)
Displays a message on the pump via communication.
Nurse call function
(TE-LF632 only)
When an alarm is activated, relay contact operates through communication
unit.
History function
Displays the operation history, etc.
AC power detector
function
Detects the presence or absence of AC power supply to the pump and displays
that status.
AC power detector
buzzer sound function
Buzzer sounds when AC power supply is provided to or disconnected from the
pump.
Purge volume upper
limit setting function
Sets the upper limit of the purge volume.
Bolus volume upper
limit setting function
Sets the upper limit of the hands on bolus volume.
Keep Vein Open
function
After activation of the Infusion Completion alarm, solution delivery is continued
at the keep vein open flow rate.
Keep Vein Open flow
rate select function
Changes the keep vein open flow rate.
During-start volume
delivered clear function
Clears the volume delivered to zero during solution delivery.
During-start flow rate
change function
Changes the flow rate during solution delivery.
Set value memory
function
Saves the current set values (e.g. flow rate, VTBI) before the power is turned
off.
Alarm melody select
function
Changes the buzzing pattern (melody) of the alarm buzzer.
Setting dial
acceleration function
Rotating the Dial while pressing the Stop switch accelerates the setting rate to
set items such as the flow rate.
Hands On Bolus
function
After the bolus flow rate is set, a bolus is delivered while the Purge switch is
pressed.
Hands Free Bolus
function
When bolus volume and bolus time are set, the flow rate is calculated and a
bolus is delivered.
Shortcut call function
Press multiple keys in combination to directly call the bolus flow rate setting
display.
Night mode function
Changes the LCD brightness for a specified time period.
Power OFF buzzer
sound function
Buzzer sounds as the power is turned off.
Use conditions
Temperature: 5 to 40°C
Humidity: 20 to 90%RH (non-condensing)
Atmospheric pressure: 70 to 106 kPa (700 to 1060 hPa)
Storage conditions*
Temperature: -20 to 45°C
Humidity: 10 to 95%RH (non-condensing)
Atmospheric pressure: 50 to 106 kPa (500 to 1060 hPa)
Transport conditions
Temperature: -20 to 60°C
Humidity: 10 to 95%RH (non-condensing)
Atmospheric pressure: 50 to 106 kPa (500 to 1060 hPa)
* A state in which the equipment is unpacked and stored for subsequent use with the main power supply unplugged.