Appendix A: Specifications
DG2040 Data Generator
AĆ5
Table AĆ1: Electrical characteristics (Cont.)
Characteristics
Description
Reference 10 MHz clock input
Connector
BNC at front panel
Input voltage range
0.2 V to 3.0 V
pĆp
Input voltage level
"
Ă10 V Max
Impedance
50
W
, AC Coupling
FrequencyĂRange
10ĂMHzĂ
±
Ă0.1ĂMHz
Edge control input
Connector
BNC at front panel
Voltage Range (typical)
-Ă1 V to +1 V
Input Impedance (typical)
50Ă
W
Frequency Range (typical)
DC to less than 500 MHz (-3 dB)
Transfer Function (typical)
See Figure AĆ2 on page AĆ9.
Display
Display area
Width: 13.2 cm (5.2 inches)
Height: 9.9 cm (3.9 inches)
Resolution
Horizontal:
640 pixels
Vertical:
480 pixels
AC line power
Rating Voltage
100Ć240 V AC
Voltage Range and
Frequency Range
90Ć250 V AC, Input voltage frequency range is 48 Hz to 63 Hz
90Ć127 V AC, Input voltage frequency range is 48 Hz to 440 Hz
Maximum power
300 W
Maximum current
4 A
Fuse rating
6A FAST, 250 V, UL 198G ( 3AG )
5A ( T ), 250 V, IEC 127
1
Clock outputs continuously regardless of the operation mode.
2
The data output duty cycle varies from 3:7 to 7:3 at 1.0 V
pĆp
during the 10
m
s just after the output has been started. The
clock continuously outputs regardless of the run mode or sequence.