Reference
DG2040 Data Generator
3Ć55
written to the destination. The current position is then moved on by the width of
the pattern in the CURRENT column, and the process is repeated.
This continues until the destination is full. If the end of the input data is reached
before the destination is full, the current position returns to the start point in the
source data.
Figure 3Ć50: Edit Code Table menu
Table 3-15 describes the parameter items in the Edit Code Table menu.
Refer to Conversion Table Examples on page C-3 for examples of how to
convert pattern data to different format.
Table 3Ć15: Edit Code Table parameters
Parameter
Function
PAST
For the template to match, the data in the source immediately behind
the current position (that is, data that has already been read) must
match this pattern.
CURRENT
For the template to match, the data in the source at the current position
must match this pattern.
NEXT
For the template to match, the data in the source at a position ahead of
the current position by the width of the pattern in the CURRENT
column must match this pattern.
PAST OUTPUT
For the template to match, the data at the end of the destination (that
is, most recently written data) must match this pattern.
OUTPUT CODE
When the whole template matches, the data specified in this column is
written to the destination.