![Tektronix 59021-10 User Manual Download Page 139](http://html1.mh-extra.com/html/tektronix/59021-10/59021-10_user-manual_1078414139.webp)
Reference
3Ć56
DG2040 Data Generator
Submenu
Item
Function
Insert Empty Line
Inserts an empty line before the line currently indicated by the block
cursor.
Delete Line
Deletes the line currently indicated by the block cursor.
Delete All Lines
Deletes all lines in the table.
NOTE
. The maximum size of the table data is 1024 lines.
Operation.
The process for editing a code conversion table is as follows:
H
The four arrow buttons are used to move the cursor
H
The general purpose knob can also be used for cursor movement
H
The CURSOR button causes the general purpose knob to switch between
controlling vertical and horizontal movement
Use this process to move the cursor to the target location and then use the
numeric keys to edit the data. Table 3-16 lists the roles of the numeric keys.
Table 3Ć16: Numeric key description
Numeric Key
Description
0
Sets the table data at the cursor to 0.
1
Sets the table data at the cursor to 1.
-
Sets the table data at the cursor to the don'tĆcare state.
The delete key clears the table data in the area that contains the cursor.
Sometimes, data at positions other than the cursor position may be changed. For
example, pressing 0 or 1 near the center of the SOURCE CONDITION
CURRENT field when the field is empty, changes data from the start of that
area to the cursor position.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com