Standard Operating Procedures
L410 UVP-E20
Document No.:
SOP-L410-0
Page EE - 89
Rev: 1
Date:JAN 18
Prepared by: LA
Checked by : CLS
PM
–
sets PCLs to MAX according to PF command, adjusts engine power to Maximum according
to engine parameters and reports „POWER SET“
–
in case of command „FLAPS 18“, sets the flap handle to 18 and after this position is reached
(according to flap position indicator) reports „FLAPS 18 SET“
–
monitors radio altimeter, pressure altimeter and airspeed indicator
Note: during PULL UP procedure the configuration of aircraft is not changed with exception of flaps in
position 42°
Summary of Contents for L410 UVP-E20