Standard Operating Procedures
L410 UVP-E20
Document No.:
SOP-L410-0
Page EE - 29
Rev: 1
Date:JAN 18
Prepared by: LA
Checked by : CLS
FDR FAULT
EC 11
Item
Action
CM
On the ground:
RECORDER circuit breaker
CHECK IN
PM
FLIGHT EXECUTION
MMEL or MEL
CM 1
In the air:
FLIGHT*
CONTINUE
PF
* After landing, report ground personnel
COMPLETE LOSS OF EFIS PRESENTATION
EC 11
Item
Action
CM
>
STANDBY INSTRUMENTS
USE
PF
CHECK DISPLAY BRIGHTNESS
MAXIMUM BRILLIANCE
PM
PFD I and PFD II circuit breakers
RESET ONE TIME IF OPEN
PM
LAND AS SOON AS POSSIBLE
Summary of Contents for L410 UVP-E20