5-8
920017-148
Operator Manual
Cycle and Control Value Programming
30. Press
CHANGE VALUES
touch pad to confirm temperature selection. The
RINSE screen appears. Display shows:
PERFORM RINSE?
NO
__indicates flashing position.
31. Press
VALUE
(up or down) touch pad to select between YES or NO.
NOTE: RINSE is non-recirculated and time setting is not adjustable.
32. Press
CHANGE VALUES
touch pad to confirm YES or NO. The FINAL
RINSE time value screen appears. Display shows:
FINAL RINSE
03:00
__indicates flashing position.
33. To enter Final Rinse treatment time, press
CURSOR
(left or right) touch pad
and
VALUE
(up or down) touch pad. Treatment time is input in minutes and
seconds within a range of 0 to 8 minutes.
34. Press
CHANGE VALUES
touch pad to confirm time selection. Final Rinse
temperature can only be adjusted in Service Mode. The VAPOR EXHAUST
time value screen appears. Display shows:
EXHAUST
01:00
__indicates flashing position.
35. To enter VAPOR EXHAUST treatment time, press
CURSOR
(left or right)
touch pad and
VALUE
(up or down) touch pad . Treatment time is input in
minutes and seconds within a range of 1 to 5 minutes.
NOTE: VAPOR EXHAUST treatment cannot be bypassed.
36. Press
CHANGE VALUES
touch pad to confirm time entry.
37. If unit is equipped with the Drying option, the DRYING time value screen
appears. Display shows:
DRYING
15:00
__indicates flashing position.
To enter DRYING treatment time, press
CURSOR
(left or right) touch pad
and
VALUE
(up or down) touch pad. Treatment time is input in minutes and
seconds within a range of 0 to 15 minutes.
38. Press
CHANGE VALUES
touch pad to confirm entry. Drying sequence
continues only if time selected is different from 0. The Drying temperature
screen appears. Display shows:
DRYING
180F
__indicates flashing position.
CHANGE
VALUES
CHANGE
VALUES
CHANGE
VALUES
CHANGE
VALUES
CHANGE
VALUES