![Splicecom 4100 Installation & Maintenance Manual Download Page 299](http://html.mh-extra.com/html/splicecom/4100/4100_installation-and-maintenance-manual_1349029299.webp)
Installation and Maintenance Manual
Maintenance & Troubleshooting
Installation and Maintenance Manual v4/0615/10
295
The version of software being used by the PCS 100 can be viewed by pressing the down arrow on the
handset; the current software version will be displayed at the bottom of the screen. Press the down
arrow or up arrow to return to the previous screen.
Upgrading locally
1
On the PCS 100 lift the handset.
2
Press the Speaker button while rebooting the unit.
3
The boot menu will be displayed
4
Press hash (#)
5
The unit will be upgraded and the reboot will complete
Upgrading remotely via Telnet
You will need to know the IP address of the PCS 100 which can be viewed via the following three
methods:
1
During power up of the phone.
2
After power up press the down arrow on the handset, the IP address and current software version
being used by the PCS 100 will be displayed on the screen. Press the down arrow or up arrow to
return to the previous screen.
3
A list of the IP address for each PCS 100 can be viewed in Manager Assist by selecting System
Utilities and then IP Addresses.
You will also need to know the
phone’s Password
which is configured in Manager within the relevant IP
Phones’ configuration form. By default this is set to 7388.
1
Within the Command Prompt on a PC connected to the system enter:
telnet <ip address of PCS 100>
eg telnet 192.168.0.247
2
When prompted for the Login name enter
diag
3
When prompted for the Password enter the password for this phone. By default this is
7388
.
(The
Password is set within the relevant Phone’s configuration form.)
4
A hash (#) will appear, indicating that the previous entries where accepted and a command can be
entered
5
Enter
upgrade loader <IP address of Call Server>
eg upgrade loader 192.168.0.1
6
When the hash (#) returns enter
upgrade now
or
upgrade now <IP address of Call Server supplying the software>
,
eg upgrade now 192.168.0.1
7
The PCS 100 will reboot. When the PCS 100 is ready press the down arrow to check the version
number to ensure the upgrade has taken place.
View the version of software via Telnet
The version of software being run on the PCS 100 can be viewed using Telnet as described above by
entering:
ver /Splicecom/xpcs
Automatic Upgrade
The upgrade of any connected Phone Module, Trunk Module, VCM, PCS 58x, PCS 57x, PCS 56x, PCS 55x,
PCS 542, PCS 410/400 and PCS 100 as described above will take place automatically at 4 am each day. At
this time a php script will be run and any module or PCS 58x/57x/56x/55x/542, PCS 410/400 and PCS 100
not running up-to-date software will be upgraded. This will take place on each module or
PCS 58x/57x/56x/55x/542, PCS 410/400 and PCS 100 that the Call Server can connect to at 4 am. If the