![Sinee EM730 Series User Manual Download Page 73](http://html1.mh-extra.com/html/sinee/em730-series/em730-series_user-manual_1280544073.webp)
User Manual of EM730/EM730E Series Inverter
73
F02.22 X3 valid delay time
0.000-30.000
s
0.000
●
F02.23 X3 invalid delay time
0.000-30.000
s
0.000
●
F02.24 X4 valid delay time
0.000-30.000
s
0.000
●
F02.25 X4 invalid delay time
0.000-30.000
s
0.000
●
F02.26 Minimum input pulse frequency
0.00 to maximum input pulse frequency F02.28
kHz
0.00
●
F02.27 Minimum input setting
–100.0 - +100.0
%
0.0
●
F02.28 Maximum input pulse frequency
0.01~100.00
kHz
50.00
●
F02.29 Maximum input setting
–100.0 - +100.0
%
100.0
●
F02.30 Pulse input filtering time
0.00 - 10.00
s
0.10
●
F02.31 Options of analog input function
Ones place: AI1
0: analog input
1: digital input (0 below 1V, 1 above 3V, the same as last
time under 1-3V)
Tens place: AI2
0: analog input
1: digital input (the same as above)
00B
〇
F02.32 Options of analog input curve
Ones place: Options of AI1 curve
0: curve 1
1: curve 2
2: curve 3
3: curve 4
Tens place: AI2 curve selection
0: curve 1
1: curve 2
2: curve 3
3: curve 4
10D
〇
F02.33 Minimum input of curve 1
0.00 - F02.35
V
0.10
●
F02.34 Minimum input setting of curve 1 –100.0 - +100.0
%
0.0
●
F02.35 Maximum input of curve 1
F02.33~10.00V
V
9.90
●
F02.36 Maximum input setting of curve 1 –100.0 - +100.0
%
100.0
●
F02.37 Minimum input of curve 2
-10.00V~F02.39
V
0.10
●
F02.38 Minimum input setting of curve 2 –100.0 - +100.0
%
0.0
●
F02.39 Maximum input of curve 2
F02.37~10.00V
V
9.90
●
F02.40 Maximum input setting of curve 2 –100.0 - +100.0
%
100.0
●