User Manual of EM730/EM730E Series Inverter
244
3 of Mode 1 (LED stop status
display parameter 2)
F12.36
Running status display parameter
4 of Mode 1 (LED stop status
display parameter 3)
0.00 - 99.99
18.08
●
F12.37
Running status display parameter
5 of Mode 1 (LED stop status
display parameter 4)
0.00 - 99.99
18.09
●
F12.32=0
: monitoring mode 0. The LED switching display and LCD small-line (7-line)
display are dependent on the settings of the function codes F12.04 to F12.08. For the selected
function codes, please refer to their parameter description.
F12.32=1
: monitoring mode 1. The LED switching display and LCD small-line (7-line)
display are dependent on the settings of the function codes F12.33 to F12.37. You can select any
function code. F12.33=18.00 means that the function code F18.00 is displayed.
Function
code
Function code name
Parameter description
Unit
Default
setting
Attribute
F12.41
Options of
UP/DOWN zero
crossing
0: prohibit zero crossing
1: allow zero crossing
0
〇
The UP/DOWN function is valid. When F12.41=0, the UP/DOWN function can reduce the
output frequency of the inverter to 0 without reversing. When F12.41=1, the UP/DOWN
function can reduce the output frequency of the inverter to 0, followed by reverse running of the
motor.
For the digital potentiometer setting, see the setting of the main frequency source A.
Function
code
Function code name
Parameter description
Unit
Default
setting
Attribute
F12.42
Frequency setting of
digital potentiometer
0.00 to maximum frequency
F00.16
Hz
0.00
×
F12.43
Digital potentiometer
torque setting
0.00-|Digital torque setting
F13.02|
%
0.0
×