![Sinee EM730 Series User Manual Download Page 120](http://html1.mh-extra.com/html/sinee/em730-series/em730-series_user-manual_1280544120.webp)
User Manual of EM730/EM730E Series Inverter
120
positive/nega
tive logic
0: positive logic, valid in the closed state/invalid in the open
state
1: Negative logic, invalid in the closed state/valid in the
open state
F17.28
Control
options of
virtual
output
terminal
D7
D6
D5
D4
D3
D2
D1
D0
11111
〇
VY8 VY7
VY6
VY5 VY4
VY3
VY2 VY1
0: Depending on the status of terminal X1-X5 (without
VY6-8)
1: depending on the output function status
F17.29
VY1 valid
delay time
0.000-30.000
s
0.000
●
F17.30
VY1 invalid
delay time
0.000-30.000
s
0.000
●
F17.31
VY2 valid
delay time
0.000-30.000
s
0.000
●
F17.32
VY2 invalid
delay time
0.000-30.000
s
0.000
●
F17.33
VY3 valid
delay time
0.000-30.000
s
0.000
●
F17.34
VY3 invalid
delay time
0.000-30.000
s
0.000
●
F17.35
VY4 valid
delay time
0.000-30.000
s
0.000
●
F17.36
VY4 invalid
delay time
0.000-30.000
s
0.000
●
F17.37
Virtual input
terminal
status
VX8 VX7
VX6
VX5 VX4 VX3 VX2
VX1
000
00000
×
0: Invalid
1: valid
F17.38
Virtual
output
terminal
status
VY8 VY7
VY6
VY5 VY4 VY3 VY2
VY1
00000
×
0: Invalid
1: valid
F18
Monitoring parameter group
F18.00
Output
frequency
0.00 to upper frequency limit
Hz
XXX
×
F18.01
Set
frequency
0.00 to maximum frequency F00.16
Hz
XXX
×
F18.03
Estimate
feedback
frequency
0.00 to upper frequency limit
Hz
XXX
×
F18.04
Output
torque
-200.0 - 200.0
%
XXX
×