User Manual of EM730/EM730E Series Inverter
55
parameter will automatically change from the current value to that indicated by F12.33. When
the inverter changes from the running status to stop status, the monitoring parameter will
automatically change from the current value to that indicated by F12.34.
4.4.2
Editing Mode
Quick change in the monitoring mode:
When F00.04 is set to “0: digital frequency setting F00.07”, turn the potentiometer key
to directly change the offset;
When F00.04 is set to “8: digital potentiometer”, turn the potentiometer key
to change
the set frequency of F12.42 digital potentiometer. In this case, turn the potentiometer key
to
enter the editing mode. The value will change from the second digit of the digital tube by default.
The digital tube corresponding to the changed digit will flash. Press the right shift key
to move to next digit on the right. Press the ESC key
to cancel change and return to the
original value. Or, press the ENTER key
to confirm the change and exit the editing mode.
The indicator will not be flicker. Press the right shift key
to enable the normal
monitoring mode: switch to next monitoring parameter. Fig. 4-6 shows the editing status in the
monitoring mode.
Flicker bit
Flicker bit
Flicker
bit
Flicker bit
Fig. 4-6 Editing Status in the Monitoring Mode
4.5
Run/Stop
After setting the parameters, press the RUN key
to enable the normal operation of