![Sinee EM730 Series User Manual Download Page 122](http://html1.mh-extra.com/html/sinee/em730-series/em730-series_user-manual_1280544122.webp)
User Manual of EM730/EM730E Series Inverter
122
state
F18.26
AI1
0.0-100.0
%
XXX
×
F18.27
AI2
0.0-100.0
%
XXX
×
F18.31
High-freque
ncy pulse
input
frequency:
kHz
0.00-100.00
kHz
XXX
×
F18.32
High-freque
ncy pulse
input
frequency:
Hz
0~65535
Hz
XXX
×
F18.33
Count value 0~65535
XXX
×
F18.34
Actual
length
0~65535
m
XXX
×
F18.35
Remaining
time of
regular
running
0.0 - 6500.0
min
XXX
×
F18.36
Rotor
position of
synchronous
motor
0.0~359.9°
XXX
×
F18.39
VF
separation
target
voltage
0 - 690
V
XXX
×
F18.40
VF
separation
output
voltage
0 - 690
V
XXX
×
F18.51
PID output
-100.0 - 100.0
%
×
F18.60
Inverter
temperature
-40 to 200
℃
0
×
F18.67
Saved
electric
energy
(MWH)
Cumulative energy saving MWH
0
~
65535 MWh
×
F18.68
Saved
electric
energy
(KWH)
Cumulative energy saving KWH
0.0
~
999.9
kWh
×