![Sinee EM730 Series User Manual Download Page 124](http://html1.mh-extra.com/html/sinee/em730-series/em730-series_user-manual_1280544124.webp)
User Manual of EM730/EM730E Series Inverter
124
E43: Material cutoff protection
E44: Cable protection
E57: Overpressure in pipeline network
E58: Under-pressure in pipeline network
E76: Short-circuit protection to ground
F19.01
Output
frequency in
protection
0.00 to upper frequency limit
Hz
0.00
×
F19.02
Output
current in
protection
0.00 to 650.00 (rated power of motor: ≤ 75 kW)
0.0 to 6500.0 (rated power of motor: > 75 kW)
A
0.00
×
F19.03
Bus voltage
in protection
0 - 1200
V
0
×
F19.04
Operating
status in
protection
0: not running
1: forward acceleration
2: reverse acceleration
3: forward deceleration
4: reverse deceleration
5: constant speed in forward running
6: reverse constant speed in reverse running
0
×
F19.05
Working
time in
protection
h
0
×
F19.06
Category of
previous
protection
Same as F19.00 parameter description
0
×
F19.07
Output
frequency in
protection
Hz
0.00
×
F19.08
Output
current in
protection
A
0.00
×
F19.09
Bus voltage
in protection
V
0
×
F19.10
Operating
status in
protection
Same as F19.04 parameter description
0
×
F19.11
Working
time in
protection
h
0
×
F19.12
Category of
two previous
protections
Same as F19.00 parameter description
0
×