![Sinee EM730 Series User Manual Download Page 154](http://html1.mh-extra.com/html/sinee/em730-series/em730-series_user-manual_1280544154.webp)
User Manual of EM730/EM730E Series Inverter
154
the UP/DOWN on the keyboard.
9
Free stop
If this function terminal is valid during inverter operation, the
output will be blocked, the inverter will stop in the free status,
and the motor will not be controlled by the inverter.
10
Reset protection
If the inverter is subject to protection and the faulty point is
eliminated, you can use this terminal to reset the inverter. This
has the same function as the Reset key on the keyboard.
11
Multi-segment
speed terminal 1
When the speed control and main frequency source A are
involved in setting, four function input terminals can be defined
as multi-segment speed terminals. The current set frequency of
the inverter depends on the code combination of these four
terminals and the settings of related function codes. Details are
given in the following table. (0/1: the current function terminal
is invalid/valid.)
★
: When a function has no corresponding input terminal
options, it is invalid (0) by default.
14
13
12
11
Set frequency of the inverter
0
0
0
0
Depending on the option (F00.04)
of the main frequency source A
0
0
0
1
Multi-segment speed 1 (F08.00)
0
0
1
0
Multi-segment speed 2 (F08.01)
0
0
1
1
Multi-segment speed 3 (F08.02)
0
1
0
0
Multi-segment speed 4 (F08.03)
0
1
0
1
Multi-segment speed 5 (F08.04)
0
1
1
0
Multi-segment speed 6 (F08.05)
0
1
1
1
Multi-segment speed 7 (F08.06)
1
0
0
0
Multi-segment speed 8 (F08.07)
1
0
0
1
Multi-segment speed 9 (F08.08)
1
0
1
0
Multi-segment speed 10 (F08.09)
1
0
1
1
Multi-segment speed 11 (F08.10)
1
1
0
0
Multi-segment speed 12 (F08.11)
1
1
0
1
Multi-segment speed 13 (F08.12)
1
1
1
0
Multi-segment speed 14 (F08.13)
1
1
1
1
Multi-segment speed 15 (F08.14)
12
Multi-segment
speed terminal 2
13
Multi-segment
speed terminal 3
14
Multi-segment
speed terminal 4
15
Multi-segment PID
terminal 1
The 4-segment PID setting can be performed via these two
terminals, as detailed in the following table (0/1: the current
function terminal is invalid/valid).
16
15
Multi-segment PID setting
0
0
Depending on the PID setting source
(F09.00)
0
1
Multi-segment PID setting 1 (F09.32)
1
0
Multi-segment PID setting 2 (F09.33)
16
Multi-segment PID
terminal 2