Function
code
Function code name
Parameter description
Unit
Default
setting
Attribute
F07.27 AVR function
0: Invalid
1: valid
2: automatic
1
〇
F07.27=0: invalid
The automatic voltage regulation (AVR) function is invalid.
F07.27=1: valid
The AVR function is continuously valid. If the input voltage is lower than the rated input
voltage, and the output frequency is greater than the corresponding frequency on the VF curve,
the inverter will output the output the maximum voltage to maximize the power output of the
motor. If the input voltage is higher than the rated input voltage, the output voltage of the
inverter will decrease, and the VF ratio will remain unchanged.
F07.27=2: automatic
The AVR function is valid automatically (invalid during deceleration): the inverter will
automatically adjust the output voltage according to changes in the actual grid voltage, to keep it
at the rated output voltage.
Function
code
Function code name
Parameter description
Unit
Default
setting
Attribute
F07.28
Stall protection
detection time
0.0-6000.0(0.0: no stall
protection detection)
s
0.0
〇
F07.29 Stall control intensity 0 - 100
%
100
〇
When the continuous stall time exceeds the set value of F07.28, the driver will report a stall
protection.
In the stall status, the driver will perform automatic control according to the set value of
F07.29. The intensity setting depends on the on-site application, instead of maximization.
7.9
Multi-segment Speed and Simple PLC Parameter Group of F08 Group
Function
code
Function code
name
Parameter description
Unit
Default
setting
Attribute
F08.00
Multi-segment
speed 1
0.00 to maximum frequency
F00.16
Hz
0.00
●
F08.01
Multi-segment
speed 2
0.00 to maximum frequency
F00.16
Hz
5.00
●
F08.02
Multi-segment
speed 3
0.00 to maximum frequency
F00.16
Hz
10.00
●
F08.03
Multi-segment
speed 4
0.00 to maximum frequency
F00.16
Hz
15.00
●
F08.04
Multi-segment
speed 5
0.00 to maximum frequency
F00.16
Hz
20.00
●
F08.05
Multi-segment
0.00 to maximum frequency
Hz
25.00
●