User Manual of EM730/EM730E Series Inverter
121
F18.05
Torque
setting
-200.0 - 200.0
%
XXX
×
F18.06
Output
current
0.00 to 650.00 (rated power of motor: ≤ 75 kW)
0.0 to 6500.0 (rated power of motor: > 75 kW)
A
XXX
×
F18.07
Output
current
percentage
0.0-300.0 (100.0 = the rated current of inverter)
%
0
×
F18.08
Output
voltage
0.0 - 690.0
V
XXX
×
F18.09
DC bus
voltage
0 - 1200
V
XXX
×
F18.10
Simple PLC
running
times
0 - 10000
XXX
×
F18.11
Simple PLC
operation
stage
1 - 15
XXX
×
F18.12
PLC running
time at the
current stage
0.0 - 6000.0
XXX
×
F18.14
Load rate
0~65535
rpm
XXX
×
F18.15
UP/DOWN
offset
frequency
0.00 to 2 * Maximum frequency F00.16
Hz
XXX
×
F18.16
PID setting
0.0 to PID maximum range
XXX
×
F18.17
PID
feedback
0.0 to PID maximum range
XXX
×
F18.18
Power meter:
MWh
0~65535
MWh
XXX
×
F18.19
Watt-hour
meter: kWh
0.0 - 999.9
kWh
XXX
×
F18.20
Output
power
-650.00~650.00
kW
XXX
×
F18.21
Output
power factor
-1.000 - 1.000
XXX
×
F18.22
Digital input
terminal
status 1
X5
X4
X3
X2
X1
XXX
×
0/1
0/1
0/1
0/1
0/1
F18.23
Digital input
terminal
status 2
*
AI2
AI1
*
*
XXX
×
*
0/1
0/1
*
0/1
F18.25
Output
terminal
*
*
R1
*
Y1
XXX
×
*
*
0/1
*
0/1