![Sinee EM730 Series User Manual Download Page 127](http://html1.mh-extra.com/html/sinee/em730-series/em730-series_user-manual_1280544127.webp)
User Manual of EM730/EM730E Series Inverter
127
detection terminal (straight wire drawing machine)
Thousands place: Brake mode
0: mode 0
1: mode 1
Myriabit: Reverse unwinding mode
0: No speed limit
1: Reverse speed limit by F27.24
F27.21
Material
cutoff
detection
delay
0.0~10.0
S
6.0
●
F27.22
Lower limit
of material
cutoff
detection
after parking
0.00 - 60.00
Hz
5.00
●
F27.23
Time of
continuous
running after
material
cutoff
0.0 - 60.0
S
10.0
●
F27.24
Frequency of
continuous
running after
material
cutoff
0.00~Fmax
Hz
5.00
●
F27.25
Brake signal
output
frequency
0.00~FUP
Hz
2.50
●
F27.26
Braking
signal
duration
0.0-100.0
S
5.0
●
F27.27
Minimum
frequency of
wiring
detection
0.00~20.00
Hz
10.00
●
F27.28
Judgment
time for
invalid cable
signal
0.1 - 20.0
S
10.0
●
F27.29
Judgment
time for
valid cable
0.1 - 20.0
S
2.0
●