Requirements for spring-loaded terminals
●
Main circuit terminals: Flat-head screwdriver with (3.5 x 0.5 mm) blade (8WA2 803)
●
Control circuit terminals: Flat-head screwdriver with (3.0 x 0.5 mm) blade
(DIN ISO 2380-1A)
Procedure for spring-loaded terminal block
Step
Instructions
Image
1
To open the clamping springs of the
spring-loaded terminal, insert the flat-
head screwdriver into the square
opening as far as it will go. Please
observe a 10° horizontal angular
deviation of the screwdriver to the oval
opening.
2
Insert the cable as far as it will go into
the oval opening and hold it in place.
3
Remove the screwdriver and pull on the
cable to ensure it is completely secure.