3RA61/3RA62 compact starter
5.4 Installing/removal
SIRIUS 3RA6 compact starter
64
System Manual, 09/2014, NEB560060102000/RS-AA/006
5.4.1.2
Installing the compact starter on a level surface (screw fastening)
Requirements
●
Look up the article numbers pertaining to the adapters for screw fastening by referring to
the list in "Adapter for screw fastening (Page 141)".
Note
The adapters for screw fastening are black and must not be confused with the gray
adapters for the infeed system for 3RA6.
●
Drill holes with thread or plug on the level surface. For details of the distances between
the drilled holes, please refer to the relevant dimension drawing in "Dimension drawings
(Page 267)".
●
4 M4 screws for mounting the direct starter on the level surface.
6 M4 screws for mounting the reversing starter on the level surface.
●
Please remember to observe the information on minimum distances in "Dimension
Procedure
Step
Instructions
Figure
1
Click the adapters for screw
fastening the compact starter into
position behind the main circuit
terminals.
2
Push the 4 mounting lugs from the
top/bottom into the adapters until
they engage.
3
Hold the device up to the surface
prepared for screw fastening.
4
Insert each screw through the
relevant holes in the mounting
lugs.
5
Screw the device onto the level
surface so that it is secure.
6
Release the actuator.