14.1 Service 1 & 2
Up/Download
->only Service 1
If an up/download with callback is carried out. In this case Sintony calls back to the number programmed
under Service 1.
Pager transmission
->only Service 2
When a pager protocol is chosen, alarms can be transmitted to a pager.
Transmit log
-> Service 1 & 2
If after an alarm the last 10 events are to be transmitted. By programming a transmission line on Service 1
&2 (engineer menu "Lines Telecom Option" (TM66) "Service 1&2" parameter), the last 10 events of the
engineer log is transmitted to Service 1 when they are triggered.
Two types of transmission can be chosen for this purpose (engineer menu "Other Telecom Options" [TM65]
"Service transmission" parameter), as follows:
z
Directly after triggering,
z
Not until after the relevant partition has been switched to unset.
Modem monitoring
->Service 1 & 2
For these function to be able to be used, a Sylcom software in modem monitoring mode must be running at
the service number.
Sylcom Access
Defines which communication device will be used to do remote connection from Sylcom to the control panel.
z
VIA SML51/61
z
VIA SMN42/SMN43
NOTE
With the A8 version it is only possible to have an SMN42 or an SML51/SML61.
With the A9 version it is possible to have an SMN42 and an SML51 (connection to Sylcom), but only
one connection is possible at a time.
14.2 Telephone
telephone numbers
->Service 1& 2
Programming the telephone numbers with the keypad, follow this description:
When changing the number all the digits not required must be overwritten with F.
If no telephone number is used, all the characters must be F.
The first character must always be a B (wait for dialing tone) or C (occupy line and wait 2 seconds). If neces-
sary, several Cs can be used.
z
F = key
@
z
B = part set key
z
C = full set key
z
B and C can also be entered by pressing
@
key several times.
Example
:
If the Control panel is connected directly to the public telephone network B94873321 must be entered to
obtain the number 94.87.33.21. If, however, the Control panel is connected to the internal exchange call
number "0" through a private automatic branch exchange, C0B94873321 must be entered to obtain the
number 94.87.33.21.
14.2.1 Site
Number
Site Number
-> Service 1& 2
The site number of the system (8-digit) must be entered here.
This number must match with the customer number of the system (Service 1 customer number) in the Syl-
com customer file.