13 ARC
ARC Alarm Receiver Central or CMS Control Management Station is used to follow
up an intervention by a security provider or the police.
[TM61] ARC 1 /
[TM62] ARC 2
This menu function enables the following parameters:
z
Serial protocol
z
Three telephone numbers
z
Transmission protocol
z
Customer number per main partition
z
Code for alarm verification
z
Audio verification
z
Automatic test call
NOTE
The offset for the start of the automatic test call is to be entered in the "Offset test call 1 Tele-
com options" (TM671) in the engineer menu.
13.1 ARC2 Backup ARC1
Backup transmission
This parameter defines whether the event is to be transmitted to Receiver 2 (emergency telephone station 2)
as increased security in the event of an unsuccessful transmission to Receiver 1 (emergency telephone
station 1). This applies only for Receiver 1 to Receiver 2 but not the other way round.
13.2 Serial Port Protocol (ARC1)
Serial Transmission uses SMN42/SMN43 Module only (SI120). Additonnaly
SML2465 can be used (SI220).
During the upgrade from A7 to A8 the parameter serial transmission is switched
off.
SMN42/SMN43 is connected to the control unit but not to the network. Initialization
and local access are set to transmission. If you try to access via the keypad, the
message “transmission on going" will be displayed. Access will be granted after
2’30”.
Callback to a free number: if the control panel does not call the Sylcom station
which initiated the callback but another Sylcom station, the error message which
will be displayed has to be ignored.