6.3.14 External Line Fault
External
Line Fault
Acts exactly the same as an internal line fault. Must be used for external communicators so that the parameters which react on
a line fault also function with external communicators. In contrast to an internal line fault, this fault remains triggered until the
input is again in the normal state.
Input triggered
Æ
line fault
Partition mode:
Unset
Part set
Full set
Effects on the following outputs when the below partition parameters are preset:
6 6 Cannot
full
set
6 Cannot
part
set
X
X
Block lock output not enabled
3
3
X
Line monitoring of transmission line
Partition parameters:
X =
Triggering regardless of the partition mode.
3 =
Triggering only if "transmission" parameter is chosen.
6 =
Triggering only if "Forced Set" parameter ->”Not Allowed” is chosen.
6.3.15 Battery Supervision (SI120 only)
Battery Supervision
(SI120 only)
Low battery is detected below 11.6 V. End of low battery is generated above 12 V. Lost of battery is also
detected.
Using additional hardware SMX23/26/29 (approvals), battery is tested every 60 seconds.
Use output ‘Supervision Batterie’ only for triggering SMX23/26/29.