Partitions
60
Siemens Building Technologies
Fire Safety & Security Products
07.2009
9.16 Room
Management
Six "rooms" can additionally be programmed for each of the 6 block lock partitions.
The rooms of a partition always refer to the partition with respect to "alarms". If only
one room is set, the burglar alarm lines of this room behave as a 24H line with in-
ternal Alarm.
When the last room is set, the partition is also automatically set. If the partition will
be set, all the "unset" rooms are automatically set at the same time. If the partition
is switched to unset, all rooms are unset. If with a partition set only one room is
switched to unset, then although the "partition" is unset the remaining rooms re-
main to set.
Not all output types can be assigned to rooms (see Output overview table).
NOTE
To assign outputs to rooms, the room parameter "Use Rooms” must preset in partition menu.
NOTE
Intern inputs with delay have the possibility to set the room to "general".
9.17 Calendar
Calendar
A calendar can be assigned to each partition. This means that the partition is unset during the programmed
time windows.