Engineer Management
91
Siemens Building Technologies
Fire Safety & Security Products
07.2009
Tel.1 Rec.2
Telephone number 1 of Receiver 2
Tel.2 Rec.2
Telephone number 2 of Receiver 2
Tel.3 Rec.2
Telephone number 3 of Receiver 2
Sylcom communication
The central control unit is communicating with Sylcom.
Carrier frequency stop
The carrier frequency was interrupted.
Connected
The central control unit has established a connection with Sylcom.
Identified
The identification with Sylcom is OK.
Transmit / receive
Transmitting or receiving with Sylcom is taking place.
Call
The central control unit detects an incoming call.
Line occupied
The telephone line is occupied.
Up/Down OK
Up/download was successful.
Transmit 2100Hz
The central control unit is transmitting the start frequency.
Transmit carrier frequency
The central control unit is transmitting the carrier frequency.
End connection
The connection to Sylcom is ended.
Callback
The central control unit makes a callback.
Hang up
The central control unit hangs up.
Send data
The central control unit is sending data.
Receive data
The central control unit is receiving data.
Transmission test end
The engineer menu is left during a transmission test. Key
X
must be pressed to end the display of the
transmission state.
19.8.6 Listen
Test
[TM86] Listen test
This menu function enables the audio/video periphery to be tested. An audio module must be fitted in the
central control unit to enable the test to be carried out.
Changeover
After activation of this test, a changeover from one verification zone to the next can be achieved by pressing
the "
Test
" key on the audio module (e.g. WMA 11). The changeover applies for audio and video.
Hearing test
The audio board provides a connection for a headset. This means that each of the verification zones can be
listened to. The microphone sensitivity can then be set as required.
Voice test
By using the voice module (e.g. SMV 11), a voice message can be output over the loudspeaker. In this case,
help text 4 is output each minute via the loudspeaker of the activated verification zone. The volume can be
set as required. If no voice module is used, a tone is output on the loudspeaker each minute for 6 seconds
each time. Steering buttons on the telephone:
z
“Star” button to quit the information and stop the dialling process
z
0” button to hang up the connection
Video test
The video pictures can be displayed on a monitor from the video module (e.g. WMV 11, WAV 61). In this
case the picture of the activated verification zone is always displayed.
Summary of Contents for SI120