Inputs
22
Siemens Building Technologies
Fire Safety & Security Products
07.2009
6.3.8 Keypad
disabled
Keypad Disable
The remote keypads of the assigned partition are switched off regardless of set/unset.
Keypad switched off means:
z
Keyboard is blocked
z
LED’s are dark with the exception of the operating indication
z
LCD shows the date and time.
Input triggered
Æ
Remote keypads of the assigned partition are switched off.
6.3.9 Lock
Supervision
Lock Supervision
This acts on the release of the block lock output and the cannot full set output. It does not affect the enforce-
ability of the part set.
Input triggered
Æ
“Blockschloss” output of the assigned partition not released (full set switching is not possi-
ble).
6.3.10 Geistiger
Verschluss
(GV)
Geistiger Verschluss
(GV)
(Intellectual Lock = IL)
This input function is used if the Sintony is connected to an external intellectual lock device.
Input triggered
Æ
Intellectual lock requested.
6.3.11 Set/Unset
Lock
Unlock Keypads
The remote keypads of the assigned partition are access able after an input pulse within a 20 second time
window.
z
Keyboard is blocked
z
LED’s are dark with the exception of the operating indication
z
LCD shows the date and time
z
The keypad is not access able in arm state.
Input triggered
Æ
Remote keypads of the assigned partition are access able within the time window.
6.3.12 Alarm Memory Reset (SI220 only)
Clear Alarm Memory
Alarms can be cancelled by this input. This input type can not be assigned to a special partition, therefore all
existing alarms are cancelled when this input is triggered (acknowledged).
6.3.13 Universal 1 / Universal 2
Universal 1
This Input will be activated when it is triggered longer than the configured "delay time” (127 seonds/minutes).
If the delay time is 0, the input is activated immediately.
NOTE
This input will not activate an alarm or buzzer, and there is no entry in the event log.
Link: The output "Universal 1" of the assigned partition will be activated regardless the state of the partition
(full set / part set / unset).
The behaviour of the output can be configured separately in the output settings.
Examples:
“Delay” time zero
Æ
direct triggering.
“Delay” time = 5 seconds
Æ
the input must be triggered for more than 5 seconds in order for an activation to
take place.
Universal 2
Acts on all “Universal 2” outputs of the assigned partition regardless of the setting. Function as for “Universal
1”.