System
70
Siemens Building Technologies
Fire Safety & Security Products
07.2009
12.15.3 Port
Enter the Sintony IP port, e.g. 8500.
12.15.4 Router Port
Enter the Sintony port router: used in special case with DSL lines and Network Address Translation (NAT)
function.
12.15.5 Current Events
Flow Events sort
All events or Restricted Events
Print Style
If is set to “enable” in the log book, CR/LF (carriage return / line field) are removed and replaced by “#”.
12.16 Type
The type shows the countries’ version
12.17 Verify Audio for Callback
IMPORTANT
This parameter has only affect when the Modules WAC11 or WAC12 are in-
stalled.
Set this parameter to “YES” when the listen in verification function for callback is
needed.
12.18 Custom Display
This information can be seen in all partitions.
Activation of a customer display
Four lines can now be defined. For each line, one of the following texts can be chosen.
z
Date
z
Time
z
Free text 1: Any name consisting of a maximum of 16 characters can be used to be displayed.
z
Free text 2: Any name consisting of a maximum of 16 characters can be used to be displayed.
In the idle mode, the normal date and time is no longer displayed, but instead both customer texts are
displayed in a 5-second cycle.
**********************************
Line 3 (Display 2 l. 1)
Line 4 (Display 2 l. 2)
**********************************
**********************************
Line 1 (Display 1 l. 1)
Line 2 (Display 1 l. 2)
**********************************
5 seconds
Summary of Contents for SI120