9. Servicing / Maintenance
252 | 268
Original Operating Manual | Edition 1.0 (01-2020) | CrimpCenter 64 SP
Demounting
Fig. 125: Filter - Cover - Opening
The filter mats are located behind covers and
are opened from the outside.
At the bottom edge of the covers there is
at least one opening.
1.
▹
Attach a small screwdriver to this opening.
2.
▹
Now lever the cover carefully on.
3.
▹
Once this has moved far enough from the side wall, grab with your fingers in the result-
ing gap.
4.
▹
Carefully remove the cover completely by pulling.
Fig. 126: Filter - with filter mat
5.
▹
Take out the filter mat.
6.
▹
Clean them or replace them with a new
one.
Installation
Fig. 127: Filter - with filter mat
1.
▹
Replace the cleaned or replaced filter
mat in the cover.
2.
▹
Turn the cover so the holes in the edge
of the frame are pointing down.
3.
▹
Gently push the filter back to its original
position in the control cabinet.