8. Commissioning
162 | 268
Original Operating Manual | Edition 1.0 (01-2020) | CrimpCenter 64 SP
Pass the wire through wire feed and swivel arm
Before inserting the wire, make sure that the beginning of the wire is as straight as possible
and that the wire has no bends. If necessary straighten the wire manually.
Operating area
1.
▹
Switch off the control voltage!
Wire feeding unit
2.
▹
Press the switch / button with the sym-
bol shown.
» The feeding belts of the wire feeding
unit move together.
3.
▹
Guide the wire through the existing
guide.
4.
▹
Continue to run the cable until it touch-
es the belts of the toothed belt pulleys.
5.
▹
Press both switches / buttons with the
symbols shown.
» The CrimpCenter will take in the wire.
Route the wire through the complete guide
tube set.
6.
▹
Hold down the buttons until the wire
comes out at the end of the guide.