When a Media Misfeed Occurs
Problem
Cause
Solution
• The media has not been
fed and does not come out
from the media output
location.
• Media rises on the platen.
• The vacuuming level of the
media is too strong.
• Media has not been set in
the roll-up unit.
• The following problems
exist with the leading edge
of roll media.
• The leading edge is
damaged.
• Adhesive tape is
sticking to it.
• The corners are
folded.
• The leading edge is
cured.
• Recommended media is
not used.
• The platen is stained.
• Lower the vacuum level.
For details about changing
the vacuum level, see
page 148 "Media
Settings".
• Set media in the roll-up
unit. For details about
setting roll media, see
page 50 "Setting Media".
• Cut the leading edge of
the roll media. For details
about cutting media, see
page 104 "Cutting
Media".
• Use recommended media.
For details about
recommended media, see
page 42 "Supported
Media".
• Clean the platen. For
details about how to do
this, see "Cleaning the
Platen", Requests for Daily
Care and Maintenance.
Misfeeds occur.
When the carriage is moving or
the media is being fed, pull up
the media holding lever.
Pull out the media to the media
output location, and then reset
the media.
When Media Is Not Fed Properly
199
Summary of Contents for Pro L5130
Page 2: ......
Page 8: ...7 Appendix Trademarks 257 6 ...
Page 50: ...1 Getting Started 48 ...
Page 90: ...DWT216 2 Basic Operations 88 ...
Page 132: ...11 Press End 3 Convenient Usage 130 ...
Page 136: ...5 Press Close 6 Press End 3 Convenient Usage 134 ...
Page 154: ... Base line position on the media guide 4 Configuring and Managing the Machine 152 ...
Page 228: ...10 DWT208 11 DWT209 12 DWT210 5 Troubleshooting 226 ...
Page 234: ...5 Troubleshooting 232 ...
Page 261: ...MEMO 259 ...
Page 262: ...MEMO 260 EN GB EN US EN AU M0BY 7564A ...
Page 263: ......
Page 264: ...EN GB EN US EN AU M0BY 7564A 2018 2019 Ricoh Co Ltd ...