SENSe:ADEMod - Subsystem
R&S FSMR
1313.9723.12
6.1-142
E-1
[SENSe:]ADEMod:DETector:PPEak:MODE
ABSolute | RELative
This command switches on absolute or relative measurement for the plus peak detector in the
modulation summary. Each time the relative measurement mode is switched on, the current
measured value is taken as a reference for the subsequent relative measurements. This command
is executed independently of the settings for the other detectors.
Example:
"
ADEM:DET:PPE:MODE REL
"
'Switches on the relative measurement
for the plus peak detector.
Characteristics:
*RST value:
ABS
SCPI:
device-specific
[SENSe:]ADEMod:DETector:PPEak:REFerence
<numeric_value>
This command sets or queries the reference value for the relative measurement for the plus peak
detector in the modulation summary.
Example:
"
ADEM ON
"
'Switches on the demodulator.
"
CALC2:FEED 'XTIM:FM:TDOM'
" 'Switches on the FM modulation summary.
"
ADEM:DET:PPE ON
"
'Switches on the plus peak detector.
"
ADEM:DET:PPE:MOD REL
"
'Switches on the relative measurement
for the plus peak detector.
"
ADEM:DET:PPE:REF 20 kHz
"
'Sets the reference value.
Characteristics:
*RST value:
0
SCPI:
device-specific
[SENSe:]ADEMod:DETector:PPEak:REFerence:AUTO
ONCE
This command uses the current measured value as a reference for the relative measurement for the
plus peak detector in the modulation summary.
Example:
"
ADEM:DET:PPE:REF:AUTO ONCE
" 'Uses the current measured value
as a reference for the relative
measurement.
Characteristics:
*RST value:
-
SCPI:
device-specific
This command is an event and therefore has no *RST value and no query.
[SENSe:]ADEMod:DETector:PPEak[:STATe]
ON | OFF
This command switches on or off the plus peak detector in the modulation summary. The command
is executed independently of the settings for the other detectors.
Example:
"
ADEM ON
"
'Switches on the demodulator.
"
CALC2:FEED 'XTIM:FM:TDOM
" 'Switches on the FM modulation summary.
"
ADEM:DET:PPE ON
"
'Switches on the plus peak detector.
Characteristics:
*RST value:
ON
SCPI:
device-specific
[SENSe:]ADEMod:DETector:REFerence
AOFF
This command switches from relative-value to absolute-value display for all measured values shown
in the modulation summary. This is also the default setting of the detectors.
Example:
"
ADEM:DET:SIN:REF AOFF
"
'Selects absolute-value display
'for all measured values shown.
Characteristics:
*RST value:
-
SCPI:
device-specific
This command is an event and therefore has no *RST value and no query.
Summary of Contents for FSMR
Page 1: ...R S FSMR Measuring Receiver Operating Manual Test Measurement Operating Manual 1313 9723 12 01...
Page 4: ......
Page 22: ......
Page 26: ...Contents Preparing for Operation R S FSMR 1155 5047 12 I 1 2 E 2 Fig 1 1 Front View...
Page 28: ...Front View R S FSMR 1166 3363 12 1 2 E 2 Fig 1 1 Front View...
Page 30: ...Front View R S FSMR 1166 3363 12 1 4 E 2 Fig 1 1 Front View...
Page 32: ...Front View R S FSMR 1166 3363 12 1 6 E 2 Fig 1 1 Front View...
Page 34: ...Front View R S FSMR 1166 3363 12 1 8 E 2 Fig 1 1 Front View...
Page 66: ......
Page 86: ......
Page 130: ...Menu Overview R S FSMR 1166 3363 12 3 42 E 3 Menu Overview another Keys MKR Key...
Page 141: ...R S FSMR Menu Overview 1166 3363 12 3 53 E 3 LOCAL Menu LOCAL...
Page 144: ......
Page 150: ......
Page 156: ......
Page 202: ......
Page 208: ......
Page 216: ......
Page 230: ......
Page 254: ......
Page 280: ......
Page 348: ......
Page 376: ...Configuration Setup R S FSMR 1166 3363 12 4 19 28 E 2...
Page 390: ......
Page 408: ......
Page 428: ......
Page 446: ......
Page 536: ......
Page 799: ......
Page 921: ......
Page 935: ......
Page 937: ...Contents Error Messages R S FSMR 1166 3363 12 I 9 2 E 1...